Hot Sale Boilers
GET 20%OFF √
Certification:ASME、ISO9001、CE、ISO、BV、CCC
Available fuel:Nature gas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
Available industries:Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.
E-mail:[email protected]
Please email or call us for your inquiry
EXAMPLE CALCULATION Fig. 1 is a waste-heat boiler operating under the following conditions: Gas flow = 200,000 lb/hr Gas inlet temperature = 1,650°F (vol% C02 =7, H2O = 18, N2 = 69, 02 = 6) Steam pressure = 500 psia Feed water temperature = 230°F The total steam generated is 63,5001b/hr. The first four rows are bare, followed by six finned tubes
Get priceThis method calculates boiler efficiency by using the basic efficiency formula-. η= (Energy output)/ (Energy input) X 100. In order to calculate boiler efficiency by this method, we divide the total energy output of a boiler by total energy input given to the boiler, multiplied by hundred. Calculation of direct efficiency-.
Get priceboiler design calculation xls – Industrial Boiler. 3/7/2017 · Boiler Design Calculation Excel Boiler Design Calculation Excel is a software selection with 63 downloads. The most lightweight of them are Bond Yield Calculator (sized at 93,794) and TexTally (sized at …
Get priceSteam Calculators: Boiler Calculator. Mar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.
Get priceDec 19, 2017 · H eating boiler calculation excel sheets: Boiler calculations Excel Sheet [] Heating capacity and boiler calculations PDF [] These excel sheets determine the amount of fuel energy required to produce steam with specified properties at a given flow rate using general boiler operational characteristics.
Get priceBoiler Water Treatment Chemical Guidelines—Part Il continued Because of the associated corrosion problems, chelants are not the preferred treatment choice. However, if the system dictates the use of chelating agents, it can feed under "starvation" conditions, i.e., no free residual in the boiler. Based on the trace level of hardness in the boiler
Get priceFormula for Calculating Fuel Consumption of Steam Boiler Kefid 11:08:41. When purchasing industrial steam boilers, customers pay more attention to the cost of steam boiler, especially the fuel consumption in operation costs.The following are the fuel calculation formulas for saturated steam boiler and superheated steam boiler.
Get priceSteam Calculators: Boiler Calculator. Mar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.
Get pricecleaning chemical into the boiler before adding water. 5. Fire the boiler intermittently at a low rate sufficient to maintain the solution at the boiling point. No steam pressure should be generated. Continue this step for at least three to five days. 6. After the boil-out period, allow a small amount of water to enter the boiler to
Get priceBecause BPSTs cogenerate two energy products (i.e., steam and power) simultaneously, they have an effective heat rate of 4,500–5,500 Btu/kWh, which represents an energy efficiency two to three times better than that of a condensing turbine, even after taking into account both boiler and turbine energy losses. (Heat rate is the amount of fuel
Get priceFormula for Calculating Fuel Consumption of Steam Boiler--ZBG
Get priceBoiler Water Treatment Chemical Guidelines—Part Il continued Because of the associated corrosion problems, chelants are not the preferred treatment choice. However, if the system dictates the use of chelating agents, it can feed under "starvation" conditions, i.e., no free residual in the boiler. Based on the trace level of hardness in the boiler
Get priceCondensing Economizer Calculator 1. Use this calculator to get a general idea of the energy and cost savings associated with installing a condensing economizer on your boiler: 2. Complete the fields below and then click "Calculate". Production Hours [hrs/yr]: [hours/day]
Get priceOnline calculator to quickly determine Boiler Efficiency. Includes 53 different calculations. Equations displayed for easy reference.
Get priceboiler contains a safety valve that, when the pressure becomes too high due to blockage or overheating, releases the excess steam. Project Description Our engineering team designed a threepass fire tube steam boiler with a capacity of 5000 kg of steam per hour and a operating pressure of 10 bar.
Get priceSteam cost/1000 Kgs. Max Gas burning rate cu m/hr. Steam cost/1000 Kgs. Max Oil burning rate lts/hr. $11.38/1000 lbs of steam. 157.14 Gal/hr.
Get priceSteam Boiler Calculator Based on Formulas Our Steam Boiler Calculators making boiler system related calculations easy, the thermodyne team created several online calculators and tools. Use following Essential industrial Steam boiler calculator …
Get priceTwo methods are available for removing dissolved oxygen from boiler water and steam systems: mechanical stripping, or deaeration (section 4.3); and chemical oxygen scavengers. Oxygen scavengers are reducing agents that react with even the very low levels of oxygen left in water by good deaeration. They are normally added to the storage section
Get priceAug 02, 2015 · Steam Boiler – chemical treatment calculations Steam boiler classification 1. High Pressure (HP) steam boiler = Pressure 40 bar; Temperature = 320o C 2. Medium Pressure (MP) steam boiler = Pressure 10 bar, Temperature = 220o C 3.
Get priceThis calculator helps you find the optimal boiler size to heat your home by area or heat loss. In the first case, the most important indicator is the rate of heating per cubic meter. In the second case, you should use the heat loss calculator in advance, get a value and enter here the power reserve (it is recommended to specify 10-15%, if you
Get priceBoiler Sizing Calculator. Standard steam output is published at 0 PSIG operating pressure and 212°F feedwater temperature however steam boiler sizing is affected by multiple variables. Steam operating pressure, feedwater (cold water) incoming temperature, and systems losses all affect the steam boiler sizing.
Get priceBoiler thermal efficiency indicates the heat exchangers effectiveness to transfer heat from the combustion process to the water or steam in a boiler, exclusive the radiation and convection losses. There are two methods to calculate a waste heat recovery boiler thermal efficiency, Positive Balance Test and Anti-Balance Test.
Get priceMar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.
Get priceFormula for Calculating Fuel Consumption of Steam Boiler Kefid 11:08:41. When purchasing industrial steam boilers, customers pay more attention to the cost of steam boiler, especially the fuel consumption in operation costs.The following are the fuel calculation formulas for saturated steam boiler and superheated steam boiler.
Get priceBoiler steam drum water level is one of the most important power plant parameters to both measure and control. Control of the proper water level in the boiler is critical for safe operation of the boiler. If the level is too low, boiler tubes will be damaged by overheating. If the
Get priceOct 23, 2020 · A boiler is designed to generate steam at 5 MPa and 400oC. A fuel is selected with a heating value of 35,000 kJ/kg burned at a rate of 600 kg/hr. Feed water into an economizer inserted in the boiler is raised from 45 oC to 150oC, while the flue gases are cooled at the same time from 400oC to 225oC.
Get priceSep 19, 2011 · • Second part is the steam cycle efficiency. Modern Rankin cycle, adopted in coal fired power plants, have efficiencies that vary from 32 % to 42 %. This depends mainly on the steam parameters. Higher steam pressure and temperatures in the range of 600 ° C and 230 bar have efficiencies around 42 %. We assume a value of 38 % for our case.
Get priceJun 24, 2019 · The output of a 10 ton boiler is 7 million kcal. Formula for calculating fuel consumption. Fuel consumption = boiler output ÷ fuel calorific value ÷ boiler thermal efficiency. According to the above method, the user can calculate the gas consumption of the gas steam boiler according to the various values provided by the boiler manufacturer
Get priceThis calculation translates the steam load (in pounds per hour) to boiler horsepower. Each boiler is given a boiler horsepower (BHP) rating based on the steam output capacity at 212°F and 0 psig. For this calculation, you will enter the steam load in pounds per hour, which will be divided by a constant of 34.5.
Get priceDec 05, 2017 · An important note on boiler sizing – all the supply piping in the basement should be insulated with a minimum of 1" of pipe insulation. A better choice would be 1-1/2" or 2" of pipe insulation. An un-insulated steam main is equal to a radiator and must be calculated and added to the above calculation. When operating a steam boiler
Get priceChapter 6 Calculations of Heat Transfer in the Furnaces of Steam Boilers According to the Laws of Radiation of Gas Volumes Anatoly N. Makarov Additional information is …
Get priceApr 15, 2020 · The loss of heat transferred to the environment S 4, taking into account heat transfer from the boiler to the environment by convection and radiation, and is calculated from the empirical formula : (24) S 4 = 10 0.36173 − 0.2912 lg Q ˙ u where Q ˙ u is the utilized heat power in the boiler and is determined using heat balance calculations
Get pricefired steam boiler by using Multi Agent System (MAS) approach (Wooldridge 2004). Our MAS realization combines two types of autonomous agents – (i) primitive agents, which can only communicate each other and perform direct algorithmic calculations or routine data performance and (ii) intelligent agents,
Get priceAug 02, 2015 · Steam Boiler – chemical treatment calculations Steam boiler classification 1. High Pressure (HP) steam boiler = Pressure 40 bar; Temperature = 320o C 2. Medium Pressure (MP) steam boiler = Pressure 10 bar, Temperature = 220o C 3.
Get pricecleaning chemical into the boiler before adding water. 5. Fire the boiler intermittently at a low rate sufficient to maintain the solution at the boiling point. No steam pressure should be generated. Continue this step for at least three to five days. 6. After the boil-out period, allow a small amount of water to enter the boiler to
Get priceMay 17, 2021 · For the high-parameter feed water and steam (the steam generators of VVER-based NPPs, once-through boilers of state-owned district power plants, CHPP drum boilers for steam pressure equal to 13.8 MPa, and CCP power units), we carried out calculations according to the Lider-APK analyzer procedure (see Table 2), which is based on measurements of
Get priceBPST = Backpressure Steam Turbine BD = Blowdown BFW = Boiler Feedwater How To Calculate The Tr 2 ue Cost of Steam Figure 1. Typical Schematic Flowsheet for a Simple Steam System In the following equations, the operating cost of the boiler is CO per hour and the process requires S pounds/hour (lb/h) of steam.
Get priceApr 17, 2019 · Many customers concern about the boiler price, the cost of the boiler and how to calculate boiler fuel consumption when they want to purchase a boiler. For the calculation of boiler fuel consumption, firstly, determine the specifications and boiler steam production, and the actual enthalpy increment of the boiler is calculated from the steam
Get priceSteam, produced in the boiler at 10 bar g, is to be used as the heating agent. If the 'From and At' rating of the boiler plant is 10 tonne/h, determine the flowrate of steam required to heat the deaerator. Before any calculations can be made to estimate the size of the deaerator, it is important to know the maximum likely feedwater requirement.
Get priceOct 06, 2014 · Heating system radiator sizing, volume, capacity, and BTUs: this article explains How to calculate the internal volume of a hot water or steam radiator. How many BTUs are provided by radiators of different types & sizes? Types of heating radiators used in buildings. Basic Radiator Water Volume vs BTU Output Data: how much water is required per BTU of …
Get price